| Safety Mats from Pinnacle
Systems NSD Safety Mat System
Breakthrough
NSD (New Switching Device) technology provides digital (on/off)
switching for safety mat applications.
NSD safety mats are designed to be machine interfaced with only
NSD safety relay controllers for normally open SPST 4-wire
safety mats. Heavy-duty electrode assembly and durable outer
shell provide excellent impact resilience and the ability to
withstand heavy loads.
No rigid steel electrodes used in the switching mechanism
that can rust and dent. Mat flexibility prevents short
outs, especially like those that occur in the corners of steel
mats. No rusting of the mat which prevents dead zones.
The NSD Safety Mat System safety relay controllers contain
two independent control circuits which allow for shut down due
to any single failure in one of the control circuits. The N.O.
output circuit is controlled by two captive contact relays in
series which are both monitored. If the contact in one relay
should stick closed (i.e., contact weld), the other relay will
shut down and the LED will indicate the fault; if the contact on
the bad relay opens back up, you must reset the power to clear
the fault. This relay contact monitoring provides a high degree
of user safety.
STTS
Safety Mat System
The NSD Safety Mat System safety relay controllers contain
two independent control circuits which allow for shut down due
to any single failure in one of the control circuits. The N. O.
output circuit is controlled by two captive contact relays in
series which are both monitored. If the contact in one relay
should stick closed (i.e., contact weld), the other relay will
shut down and the LED will indicate the fault; if the contact on
the bad relay opens back up, you must reset the power to clear
the fault. This relay contact monitoring provides a high degree
of user safety.
STTS Controller Features and Benefits
- Safety Category IV design controller provides the user
with message display diagnostics needed to maintain
productivity and reduce downtime
- Individual Mat Diagnostics and Indicators offers the
unique ability to indicate open circuits on individual mats
to make diagnostics easier
- Compact Size -- Designed for safety mat layouts of up to
eight mats
- Rugged Design -- For tough industrial environments with
an enclosure rated IP 65 and NEMA 12 or Din-rail mount
- Multiple Power Inputs and Operation Modes accommodates a
variety of power requirements, including 120 VAC, 240 VAC
and 24 VDC and offers two modes of operation (automatic
restart and guard only) in one unit
- One, two or three zone
Contact Guardomation
Please contact
Guardomation for technical, applications engineering and
sales assistance for your machine guarding and safety requirements. |